Bentley SewerCAD CONNECT Edition Help

Zoom Dependent Visibility

Available through the Properties dialog box of each layer in the Element Symbology manager, this feature can be used to cause elements, decorations, and annotations to only appear in the drawing pane when the view is within the zoom range specified by the Minimum and Maximum Zoom values.

  • Enabled: Set to true to enable and set to false to disable Zoom Dependent Visibility.
  • Zoom Out Limit (%): The lowest zoom level at which the element will appear in the drawing pane.
  • Zoom In Limit (%) : The highest zoom level at which the element will appear in the drawing pane.
  • Apply to Element: Set to true to apply the zoom minimums and maximums to the symbols in the drawing.
  • Apply to Decorations: Set to true to apply the zoom minimums and maximums to flow arrows, check valves, and constituent sources in the drawing.
  • Apply to Annotations: Set to true to apply the zoom minimums and maximums to labels in the drawing.